Example: Edit Points
The following example introduces how to use Edit Points to create an arbitrary
waveform fulfilling the following conditions.
Operation Procedures:
1. Press Arb and use to open the 2/2 menu page; then press Create New
Cycle Period, use the numeric keyboard to input 12 and select the unit
μs from the pop-up menu.
2. Press High VLimit, use the numeric keyboard to input 4 and select the unit
V from the pop-up menu.
3. Press Low VLimit, use the numeric keyboard to input -2 and select the unit
V from the pop-up menu.
4. Press Init #Points , use the numeric keyboard to input 4 and press OK.
Note: at this point, a -2 V level line appears.
5. Press Interp to select Linear.
6. Press Edit Points to enter the “Edit Points” interface.
Parameter
Value
Cycle Period
12μs
High VLimit
4V
Low VLImit
-2V
Interp
Linear
Point 1
0s, 0V
Point 2
4μs, 4V
Point 3
8μs, 0V
Point 4
10μs, -2V