Instructions
RIGOL  Chapter 2 Front Panel Operations 
2-64     DG2000 User Guide 
Figure 2-11 N Cycle Burst 
For N cycle burst, "Internal", "External", or "Manual" trigger source could be selected. 
Besides, you can also set the parameters of "Period" (internal trigger), "Delay", 
"Trig In" (external trigger) and "Trig Out" (internal and manual trigger). 
Infinite Burst 
In Infinite mode, the cycle number of the waveform is set as an infinite value. The 
generator outputs a continuous waveform after receiving a trigger signal. 
When the Shift key is illuminated, press Home/Menu  Burst  "Infinite" to 
enable the Infinite burst. The instrument will set the trigger source to "Manual" 
automatically. A diagram of an infinite cycle burst will appear on the screen. 
Figure 2-12 Infinite Burst 
For the Infinite burst, "External" or "Manual" trigger source could be selected. 
Besides, users can set the parameters of "Delay", "Trig In" (external trigger), and 
"Trig Out" (manual trigger). 