Instructions
RIGOL  Chapter 2 Front Panel Operations 
2-54     DG2000 User Guide 
To Select Modulation Source 
Tap the Source parameter selection field to select an "Internal" or "External" 
modulation source. 
1.  Internal Source 
When internal modulation source is selected, tap the Mod.Wave parameter 
selection field to select Sine, Square, Triangle, UpRamp, DnRamp, Noise, or Arb 
as modulating waveform. By default, Sine is selected. 
  Square: 50% duty cycle. 
  Triangle: 50% symmetry. 
  UpRamp: 100% symmetry. 
  DnRamp: 0% symmetry. 
  Arb: the arbitrary waveform selected for the current channel. 
Note: Noise can be used as the modulating waveform but cannot be used as 
carrier waveform. 
2.  External Source 
When the external modulation source is selected, Mod.Wave and Mod.Freq 
will be grayed out and disabled. The generator receives the external modulating 
signal from the rear-panel [CH1/Sync/Ext Mod/Trig/FSK] connector. At this 
time, the width deviation or the duty cycle deviation of the modulated waveform 
is controlled by the ±5 V signal level on the connector. For example, if the width 
deviation is set to 10 s, the +5 V signal level corresponds to a 10 s width 
variation. 
To Set Modulating Waveform Frequency 
When the internal modulation source is selected, tap the Mod.Freq parameter input 
field and use the numeric keypad to set the modulating waveform frequency. 
  You can also use the arrow keys and the knob to input a desired frequency 
value. 
  The modulating waveform frequency ranges from 2 mHz to 1 MHz, and the 
default value is 100 Hz. 
Note: When the external modulation source is selected, this menu will be grayed out 
and disabled. 