Instructions
Chapter 2 Command System  RIGOL 
DG2000 Programming Guide  2-45 
:OUTPut[<n>]:VOLLimit:LOW 
Syntax   
:OUTPut[<n>]:VOLLimit:LOW <amp> 
:OUTPut[<n>]:VOLLimit:LOW? 
Description   
Sets the low level amplitude of voltage limit. 
Queries the low level amplitude of voltage limit. 
Parameter 
Name 
Type 
Range 
Default 
[<n>] 
Discrete 
1|2 
1 
<amp> 
Real 
Refer to "Remarks". 
0 V 
Remarks   
  When [<n>] is omitted, the commands set and query the related parameters of CH1 by default. 
  The range of low level limit depends on the current amplitude and offset settings. 
Return Format 
The query returns the low level limit value in scientific notation with 7 effective digits. For example, 
-1.000000E+00, indicating that the high level limit value is -1 V. 
Example 
:OUTP1:VOLLimit:LOW          /*Sets the low level amplitude of voltage limit of CH1 to -1 V.*/ 
:OUTP1:VOLLimit:LOW?      /*Queries the low level amplitude of voltage limit of CH1 and returns 
-1.000000E+00.*/ 
:OUTPut[<n>]:VOLLimit[:STATe] 
Syntax   
:OUTPut[<n>]:VOLLimit[:STATe] {ON|1|OFF|0} 
:OUTPut[<n>]:VOLLimit[:STATe]? 
Description   
Enables or disables the voltage limit. 
Queries the on/off status of the voltage limit. 
Parameter 
Name 
Type 
Range 
Default 
[<n>] 
Discrete 
1|2 
1 
{ON|1|OFF|0} 
Bool 
ON|1|OFF|0 
ON 
Remarks   
When [<n>] is omitted, the commands set and query the related parameters of CH1 by default. 
Return Format 
The query returns ON or OFF. 
Example 
:OUTP1:VOLLimit?   /*Queries the on/off status of the voltage limit of CH1 and the query returns OFF.*/ 
:OUTP1:VOLLimit ON /*Enables the voltage limit of CH1.*/ 
:OUTP1:VOLLimit?   /*Queries the on/off status of the voltage limit of CH1 and the query returns ON.*/ 