Instructions
RIGOL  Chapter 2 Command System 
2-44  DG2000 Programming Guide 
Parameter 
Name 
Type 
Range 
Default 
[<n>] 
Discrete 
1|2 
1 
{ON|1|OFF|0} 
Bool 
ON|1|OFF|0 
ON 
Remarks   
  DG2000 can output the basic waveforms (except Noise), arb waveforms, harmonics, sweep waveforms, 
burst waveforms, and the sync signal of the modulated waveforms from a single channel or the dual 
channels at the same time. The sync signal will be output from the rear-panel [Sync/Ext 
Mod/Trig/FSK] connector of the corresponding channel. 
  When [<n>] is omitted, the commands set and query the related parameters of CH1 by default. 
  When the carrier frequency is greater than 30 MHz, the sync signal will be output in frequency dividing 
way. 
  If the sync signal is disabled, the marker signal used in the sweep is also disabled. 
Return Format 
The query returns ON or OFF. 
Example 
:OUTP1:SYNC 1         /*Enables to output the sync signal from the rear-panel [CH1/Sync/Ext 
Mod/Trig/FSK] connector.*/ 
:OUTP1:SYNC?  /*Queries the output status of the sync signal output from the rear-panel 
[CH1/Sync/Ext Mod/Trig/FSK] connector and returns ON.*/ 
:OUTP1:SYNC OFF  /*Disables to output the sync signal from the rear-panel [CH1/Sync/Ext 
Mod/Trig/FSK] connector.*/ 
:OUTP1:SYNC?       /*Queries the output status of the sync signal output from the rear-panel 
[CH1/Sync/Ext Mod/Trig/FSK] connector and returns OFF.*/ 
:OUTPut[<n>]:VOLLimit:HIGH 
Syntax   
:OUTPut[<n>]:VOLLimit:HIGH <amp> 
:OUTPut[<n>]:VOLLimit:HIGH? 
Description   
Sets the high level amplitude of voltage limit. 
Queries the high level amplitude of voltage limit. 
Parameter 
Name 
Type 
Range 
Default 
[<n>] 
Discrete 
1|2 
1 
<amp> 
Real 
Refer to "Remarks". 
0 V 
Remarks   
  When [<n>] is omitted, the commands set and query the related parameters of CH1 by default. 
  The range of high level limit depends on the current amplitude and offset settings. 
Return Format 
The query returns the high level limit value in scientific notation with 7 effective digits. For example, 
1.000000E+00, indicating that the high level limit value is 1 V. 
Example 
:OUTP1:VOLLimit:HIGH 1 /*Sets the high level amplitude of voltage limit of CH1 to 1 V.*/ 
:OUTP1:VOLLimit:HIGH?      /*Queries the high level amplitude of voltage limit of CH1 and returns 
1.000000E+00.*/ 