Instructions
Chapter 2 Command System  RIGOL 
DG2000 Programming Guide  2-133 
[:SOURce[<n>]]:SWEep:TRIGger:SOURce 
Syntax 
[:SOURce[<n>]]:SWEep:TRIGger:SOURce {INTernal|EXTernal|MANual} 
[:SOURce[<n>]]:SWEep:TRIGger:SOURce? 
Description 
Sets the sweep trigger source of the specified channel to Internal (INTernal), External (EXTernal), or 
Manual (MANual). 
Queries the trigger source of the sweep of the specified channel. 
Parameter 
Name 
Type 
Range 
Default 
[<n>] 
Discrete 
1|2 
1 
{INTernal|EXTernal|MANual} 
Discrete 
INTernal|EXTernal|MANual 
INTernal 
Remarks   
  The generator outputs continuous sweep waveforms when the internal trigger is selected. The trigger 
period is determined by the specified sweep time (
[:SOURce[<n>]]:SWEep:TIME), return time 
(
[:SOURce[<n>]]:SWEep:RTIMe), start hold ([:SOURce[<n>]]:SWEep:HTIMe:STARt), and stop hold 
time (
[:SOURce[<n>]]:SWEep:HTIMe[:STOP]).   
  In the External trigger, the signal generator receives the trigger signal input from the rear-panel 
[Sync/Ext Mod/Trig/FSK] connector of the specified channel. Once it receives a TTL pulse 
(
[:SOURce[<n>]]:SWEep:TRIGger:SLOPe) with a specified polarity, a sweep is initiated. 
  In the Manual trigger, the instrument initiates a sweep on the corresponding channel immediately each 
time the trigger command (
[:SOURce[<n>]]:SWEep:TRIGger[:IMMediate]) is sent (the trigger 
command is only valid when the output of the specified channel is enabled). 
  When [:SOURce[<n>]] or [<n>] is omitted, the system sets the related parameters of CH1 by default. 
Return Format 
The query returns INT, EXT, or MAN. 
Example 
:SOUR1:SWE:TRIG:SOUR INT      /*Sets the trigger source of the sweep of CH1 to Internal.*/ 
:SOUR1:SWE:TRIG:SOUR?    /*Queries the trigger source of the sweep of CH1 and the query returns 
INT.*/ 