User`s guide
RIGOL
© 2008 RIGOL Technologies, Inc. 2-33
User’s Guide for DG10× 2 Series
Table 2-15 Setting the FM parameters
Menu
Settings
Explanation
Type
FSK
Choose Frequency Shift Keying Modulation
SrcInt
HopFreq
Set the Hop Frequency Range
(Internal Source: Square with 50% duty
cycle)
FSK Rate
Set the frequency at which the output
frequency shifts between the carrier
frequency and the jumping frequency:
2mHz~50kHz.
SrcExt
HopFreq
Choose External modulation, the
modulating waveform is inputted form the
[Ext Trig/FSK/Burst] port on the rear
panel. Only “HopFreq” needs to be set.
Press View, in the Graph Mode, the waveform is shown in the following figure.
Figure 2-40
Waveform Parameter in the Graph Mode
FSK Frequency
Hop Frequency