User`s guide
RIGOL
© 2008 RIGOL Technologies, Inc.
User’s Guide for DG10× 2 Series
3-15
Example 11: To Generate a Burst Waveform
How to generate a Burst Waveform that has 3 Cycles, 0° Phase and the period is
10ms.
The operation steps:
1. Choose the Burst Function.
Press Square, and choose the Square Waveform as the Burst Function.
The default setting of the Source is Internal.
2. Set the Parameters of the Burst Function.
Use the default values. You can view all the parameters in the Graph mode.
3. Set the Sweep Mode.
Press Burst NCycle choose N-Cycle Mode. Please note that the message shown
on the top left side of the screen is “N Cycle”.
4. Set the Burst Period.
Press Period, use the keypad to enter “10”, choose the unit “ms” and set the
Period as 10 ms.
5. Set the Start Phase.
Press Phase, use the keypad to enter “0”, choose the unit “°”, setting the Start
phase as 0°.
6. Set the Burst Cycles.
Press Cycles, use the keypad to enter “3”, choose the unit “Cyc”, setting the Burst
Cycle as 3.
7. Set the Delay.
Press Delay, use the keypad to enter “200”, choose the unit “μs”, setting the Burst
Delay as 200μs.
After finishing the above settings, the instrument generates the specified 3-Cycle
Burst waveform with a period of 10ms. press View, the generated waveform is shown
in Figure 3-12.