Specifications
RIGOL DG10X2 Commands System
Programming Guide for DG10X2
2-48
Format
Function
Set the initial phase of burst.
Explanations
<angle> is the phase for user to set, the unit is degree.
MIN=-180°, MAX=180°.
Example
BURS:PHAS 150
8. BURSt:PHASe?
Command
Format
BURSt:PHASe? [MINimum|MAXimum]
Function
Query the initial phase of burst.
Return Value
The query returns the initial phase of burst in the form of scientific
notation in degree such as: 1.500000e+02.
9. BURSt:STATe
Command
Format
BURSt:STATe {OFF|ON}
Function
Enable or disable burst mode.
Example
BURS:STAT OFF
10. BURSt:STATe?
Command
Format
BURSt:STATe?
Function
Query the state of burst mode.
Return Value
The query returns OFF or ON.
11. BURSt:GATE:POLarity
Command
Format
BURSt:GATE:POLarity {NORMal|INVerted}
Function
Set the polarity of external gating signal from [Ext Trig/FSK/Burst]
conncetor on the rear panel, the default is NORMal.
Example
BURS:GATE:POL INV
12. BURSt:GATE:POLarity?
Command
Format
BURSt:GATE:POLarity?
Function
Query the polarity of external gating signal from the rear panel.
Return Value
The query returns NORM or INV.