Specifications

RIGOL DG10X2 Commands System
Programming Guide for DG10X2
2-42
SWEep
In frequency sweep mode, the generator “steps” from the start frequency to the stop
frequency at a sweep rate that you specified. You can sweep up or down in frequency,
and with either linear or logarithmic spacing.
In addition, you can configure the generator to output a single sweep (one pass from
start frequency to stop frequency) by applying an external or manual trigger. The
generator can produce a frequency sweep for sine, square, ramp or arbitrary
waveforms (pulse, noise, and DC are not allowed) from CH1.
DG10X2 supports following SWEep commands:
1. SWEep:SPACing
2. SWEep:SPACing?
3. SWEep:TIME
4. SWEep:TIME?
5. SWEep:STATe
6. SWEep:STATe?
The detailed information of each command are:
1. SWEep:SPACing
Command
Format
SWEep:SPACing {LINear|LOGarithmic}
Function
Select linear or logarithmic spacing for the sweep, the default is
Linear.
Example
SWE:SPAC LIN
2. SWEep:SPACing?
Command
Format
SWEep:SPACing?
Function
Query current sweep mode.
Return Value
The query returns LINEAR or LOG.
3. SWEep:TIME
Command
Format
SWEep:TIME {<seconds>|MINimum|MAXimum}