Specifications

DG10X2 Commands System RIGOL
Programming Guide for DG10X2
2-37
Function
Select the internal modulation wave of PM.
Explanations
In internal modulation source mode, the modulation wave could be
sine, square, ramp, negative ramp, triangle, noise or arbitrary
wave, the default is sine.
Example
PM:INT:FUNC SQU
4. PM:INTernal:FUNCtion?
Command
Format
PM:INTernal:FUNCtion?
Function
Query the internal modulation wave of PM that has been selected.
Return Value
The query returns SIN, SQU, RAMP, NRAM, TRI, NOIS or USER.
5. PM:INTernal:FREQuency
Command
Format
PM:INTernal:FREQuency {<frequency>|MINimum|MAXimum}
Function
Set the frequency of internal modulation of PM and in Hz.
Explanations
Frequency range: 2mHz 20kHz
Example
PM:INT:FREQ 200
6. PM:INTernal:FREQuency?
Command
Format
PM:INTernal:FREQuency?
Function
Query the frequency of internal modulation of PM.
Return Value
The query returns the internal modulation frequency of PM in the
form of scientific notation, such as: 2.000000e+02.
7. PM:DEViation
Command
Format
PM:DEViation {<phase deviation>|MINimum|MAXimum}
Function
Set the phase deviation of PM and in degree.
Explanations
Phase deviation range: 360°
Example
PM:DEV 180
8. PM:DEViation?
Command
Format
PM:DEViation? [MINimum|MAXimum]
Function
Query the phase deviation of PM.