Specifications
DG10X2 Commands System RIGOL
Programming Guide for DG10X2
2-17
VOLTage
VOLTage commands are used for setting the voltage amplitude, offset, high level,
low level, or setting the voltage unit for each channel.
DG10X2 supports following VOLTage commands:
1. VOLTage
2. VOLTage?
3. VOLTage:HIGH
4. VOLTage:HIGH?
5. VOLTage:LOW
6. VOLTage:LOW?
7. VOLTage:OFFSet
8. VOLTage:OFFSet?
9. VOLTage:UNIT
10. VOLTage:UNIT?
11. VOLTage:CH2
12. VOLTage:CH2?
13. VOLTage:HIGH:CH2
14. VOLTage:HIGH:CH2?
15. VOLTage:LOW:CH2
16. VOLTage:LOW:CH2?
17. VOLTage:OFFSet:CH2
18. VOLTage:OFFSet:CH2?
19. VOLTage:UNIT:CH2
20. VOLTage:UNIT:CH2?
The detailed information of each command are:
1. VOLTage
Command
Format
VOLTage {<amplitude>|MINimum|MAXimum}
Function
Set the amplitude from CH1 in Vpp.
Explanations
MIN selects the minimum amplitude. MAX selects the maximum
amplitude for the selected function.
Unit
VPP, VRMS or DBM. Note that DBM could be used only in non-high
resistance. The unit of voltage could be changed via sending