Specifications
RIGOL DG10X2 Commands System
Programming Guide for DG10X2
2-8
impression on this command, a value or “DEFault” must be
specified.
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:DC:CH2 DEF,DEF,1.5
15. APPLy:USER:CH2
Command
Format
APPLy:USER:CH2 [<frequency>[,<amplitude>[,<offset>]]]
Function
Generate an arbitrary wave selected by FUNCtion:USER:CH2
command with specific frequency, amplitude and DC offset.
Explanations
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:USER:CH2 1000,5.0,-1.5
16. APPLy:CH2?
Command
Format
APPLy:CH2?
Function
Query the current configuration of CH2 and the type of waves
outputted.
Explanations
The query returns a character string with double quotation marks,
including function, frequency, amplitude and offset.
Example
CH2:"SIN,1.000000e+03,5.000000e+00,-1.500000e+00"