Specifications
DG10X2 Commands System RIGOL
Programming Guide for DG10X2
2-5
Format
Function
Generate Gaussian noise with specific amplitude and DC offset.
Explanations
Although the frequency parameter made no impression on this
command, a value or “DEFault” must be specified. (noise
function has 5MHz of bandwidth)
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:NOIS DEF,5.0,2.0
6. APPLy:DC
Command
Format
APPLy:DC [<frequency|DEFault>[,<amplitude>|DEFault>[,<
offset>]]]
Function
Generate a DC with electrical level specified by < offset > parameter
via CH1.
Explanations
Although the frequency and amplitude parameter made no
impression on this command, a value or “DEFault” must be
specified.
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:DC DEF,DEF,-2.5
7. APPLy:USER
Command
Format
APPLy:USER [<frequency>[,<amplitude>[,<offset>]]]
Function
Generate an arbitrary wave selected by FUNCtion:USER command
with specific frequency, amplitude and DC offset.
Explanations
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:USER 1000,5.0,-1.5
8. APPLy?