Specifications

RIGOL DG10X2 Commands System
Programming Guide for DG10X2
2-4
2. APPLy:SQUare
Command
Format
APPLy:SQUare [<frequency>[,<amplitude>[,<offset>]]]
Function
Generate a square wave with specific frequency, amplitude and DC
offset via CH1 and cover the current duty cycle settings and select
50% automaticly.
Explanations
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:SQU 1000,5.0,-1.5
3. APPLy:RAMP
Command
Format
APPLy:RAMP [<frequency>[,<amplitude>[,<offset>]]]
Function
Generate a ramp wave with specific frequency, amplitude and DC
offset via CH1 and cover the current symmetry settings and select
50% automaticly.
Explanations
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:RAMP 1000,5.0,-1.5
4. APPLy:PULSe
Command
Format
APPLy:PULSe [<frequency>[,<amplitude>[,<offset>]]]
Function
Generate a pulse wave with specific frequency, amplitude and DC
offset via CH1.
Explanations
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude>, <offset> are:
Hz, Vpp, V
DC
.
Example
APPL:PULS 1000,5.0,-1.5
5. APPLy:NOISe
Command