Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- DG1000Z Series Overview
- Document Overview
- Chapter 1 Quick Start
- Chapter 2 Front Panel Operations
- To Output Basic Waveform
- To Select Output Channel
- To Select Basic Waveform
- To Set Frequency/Period
- To Set Amplitude/High Level
- To Set Offset/Low Level
- To Set Start Phase
- Align Phase
- To Set Duty Cycle (Square)
- To Set Symmetry (Ramp)
- To Set Pulse Width/Duty Cycle (Pulse)
- To Set Leading/Trailing Edge Time (Pulse)
- To Enable Output
- Example: To Output Sine Waveform
- To Output Arbitrary Waveform
- To Output Harmonic
- Modulation
- Sweep
- Burst
- Counter
- Store and Recall
- Utility and System Settings
- To Install the Option
- To Lock the Keyboard
- To Output Basic Waveform
- Chapter 3 Remote Control
- Chapter 4 Troubleshooting
- Chapter 5 Specifications
- Chapter 6 Appendix
- Index
Chapter 2 Front Panel Operations RIGOL
DG1000Z User’s Guide 2-105
Press AutoIP to select “On” or “Off” to turn AutoIP mode on or off. The
default is “On”. When DHCP and AutoIP modes are turned on at the same
time, the instrument will first use DHCP mode. Therefore, to enable this
mode, set DHCP as “Off”.
3. ManualIP
In ManualIP mode, the LAN parameters of the generator, e.g. IP address,
are defined by users.
Press ManualIP to select “On” or “Off” to turn ManualIP mode on or off.
The default is “Off”. If all the three IP configuration modes are “On”, the
priority of parameters configuration from high to low is “DHCP”, “AutoIP”
and “ManualIP”. Therefore, to enable this mode, set DHCP and AutoIP as
“Off”.
The IP address format is nnn.nnn.nnn.nnn. The first nnn ranges from 1 to
223 (except 127) and the other three nnn range from 0 to 255. It is
recommended that users acquire an available IP address from their network
administrator.
Press IP Address and use the direction keys and numeric keyboard or
knob to enter your desired IP address. The setting is stored in non-volatile
memory and will be loaded automatically when the generator is powered on
the next time if DHCP and AutoIP are set as “Off”.
TIPS:
If all the three IP configuration modes are “On”, the priority of parameters
configuration from high to low is “DHCP”, “AutoIP” and “ManualIP”.
The three IP configuration modes cannot be set as “Off” at the same time.
To Set Subnet Mask
In ManualIP mode, the subnet mask could be manually set.
The format of subnet mask is nnn.nnn.nnn.nnn, wherein nnn ranges from 0 to
255. It is recommended that users acquire an available subnet mask from their
network administrator.
Press SubMask and use the direction keys and numeric keyboard or knob to
enter your desired subnet mask. The setting is stored in non-volatile memory
and will be automatically loaded when the generator is powered on the next
time if DHCP and AutoIP are set as “Off”.
To Set Default Gateway
In ManualIP mode, the default gateway could be manually set.
The format of default gateway is nnn.nnn.nnn.nnn, wherein the first nnn ranges
from 1 to 223 (except 127) and the other three nnn range from 0 to 255. It is