User manual

RIGOL DG1022 Commands System
Programming Guide for DG1022
2-60
"CARDIAC","A","B","C","D","E","F","G","H","I","J".
6. DATA:RENAME
Command
Format
DATA:RENAME <destination arb name>,<new arb name>
Function
Rename an arbitrary wave.
Example
DATA:RENAME old, new
7. DATA:NVOLatile:CATalog?
Command
Format
DATA:NVOLatile:CATalog?
Function
Query the names of all user-defined arbitrary waveforms
downloaded to non-volatile memory.
Return Value
The query returns the quoted names of up to 10 waveforms such
as: "A","B","C","D","E","F","G","H","I","J".
8. DATA:NVOLatile:FREE?
Command
Format
DATA:NVOLatile:FREE?
Function
Query the number of non-volatile memory that is available for
saving user-defined waveforms.
Return Value
The query returns 0 (denotes full memory), 1, 2, 3, 4, 5, 6, 7, 8, 9,
10.
9. DATA:ATTRibute:POINts?
Command
Format
DATA:ATTRibute:POINts? <destination arb name>
Function
Query the number of points in the specified arbitrary waveform.
Return Value
The query return a value within 0~524,288, such as 4096.
10. DATA:LOAD
Command
Format
DATA:LOAD [<destination arb name>]
Function
Upload the specified arbitrary wave to the application software.