User manual

DG1022 Commands System RIGOL
Programming Guide for DG1022
2-43
Command
Format
PM:INTernal:FREQuency?
Function
Query the frequency of internal modulation of PM.
Return Value
The query returns the internal modulation frequency of PM in the
form of scientific notation, such as: 2.000000e+02.
7. PM:DEViation
Command
Format
PM:DEViation {<phase deviation>|MINimum|MAXimum}
Function
Set the phase deviation of PM and in degree.
Explanations
Phase deviation range: 360°
Example
PM:DEV 180
8. PM:DEViation?
Command
Format
PM:DEViation? [MINimum|MAXimum]
Function
Query the phase deviation of PM.
Return Value
The query returns the phase deviation of PM in the form of
scientific notation in degree, such as: 1.800000e+02.
9. PM:STATe
Command
Format
PM:STATe {OFF|ON}
Function
Disable or enable PM function.
Example
PM:STAT OFF
10. PM:STATe?
Command
Format
PM:STATe?
Function
Query the modulation state of PM.
Return Value
The query returns OFF or ON.