User manual
RIGOL DG1022 Commands System
Programming Guide for DG1022
2-40
Command
Format
FM:INTernal:FREQuency?
Function
Query the frequency of internal modulation of FM.
Return Value
The query returns the percent of the frequency of FM internal
modulation in the form of scientific notation, such as:
2.000000e+02
7. FM:DEViation
Command
Format
FM:DEViation{<frequency deviation of peak value>
|MINimum|MAXimum}
Function
Set the frequency deviation of peak value of FM in Hz.
Example
FM:DEV 100
8. FM:DEViation?
Command
Format
FM:DEViation? [MINimum|MAXimum]
Function
Query the frequency deviation of peak value of FM.
Return Value
The query returns the frequency deviation of peak value of FM in
the form of scientific notation and in Hz, such as: 1.000000e+02
9. FM:STATe
Command
Format
FM:STATe {OFF|ON}
Function
Disable or enable FM function.
Example
FM:STAT OFF
10. FM:STATe?
Command
Format
FM:STATe?
Function
Query the modulation state of FM.
Return Value
The query returns OFF or ON.