Datasheet
E-stop / mat-, edges-control relays
Printing 11.03.2016
DEVICE SAFE CM
Safet
y
controller for safet
y
mats and safet
y
bars with a
APPLICATIONS
or a finalizing resistor 8,2 kOhms
APPROVALS
CE, TÜV, UL, C-UL
CONTACTS
4 safety semiconductor outputs (OSSD)
LED indicators for status and supply diagnostic
SPECIAL CHARACTERISTICS
wearless semiconductor outputs, "AND" function
between several SAFE C possible, automatic start possible
LED
Power, channel 1 and channel 2
24 V DC ( + 25 - 20 % )
OPERATING VOLTAGE
Overvoltage protection
POWER CONSUMPTION
ca. 3 W
START UP DELAY / FALLBACK TIME
<30 ms / <140 ms (single channel <360 ms)
CONTACT CAPACITY max.
total current 1,8 A
CONTACT CAPACITY min. at 24 V DC (*)
infinite
SIMULTANEITY
not necessary
ENVIRONMENTAL TEMPERATURE
-25°C to + 55°C
SWITCHING CAPACITY
to 43 W
CONTACT SECURITY
short circuit proof
OPERATING MODE
(*) We offer all devices who have a CONTACT CAPACITY of
min. 100 mA at 24 V DC with hard gold-plated contacts.
In this way the CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
4 wire technology with wire break protection or 2 wire technology and
terminating resistor with wire break protection are optional. Start
monitoring and automatic start are optional. For monitoring of external
relays to n.c. contacts are put in series of the start circuit "AND"
function among several SAFE C is possible.
A1 + 24 V DC
A2 0 V DC
S33
S36 S37
14 34
K1
K2
A2
K1
K2
S34
S22S12
S11
S21 S32
8k2
K1
K2
S35
FUNCTION CIRCUIT DIAGRAM
A1 A2
Power
Input circuits
S12 S22 S34 S35 S36
Output
circuits
Combination
circuit
S11 S21 S33
MCU1
<Controller 1>
MCU2
<Controller 2>
Safety output circuits
14
24
34
44
S32S37
Certifications according to
Safety relevant substance data
Depending on wiring (only max. achievable values are given)
EN ISO 13849-1 / EN 61508: PLe, Cat. 4 / SIL3
MTTFd: 163 years / high, DC: high, CCF: achieved,
PFH: 2,87*10
-9
1
/
h
, PFD: 2,01*10
-6
1
/
h,
SFF: 0,9573