Datasheet
Control devices for safety light barriers
Printing 11.03.2016
DEVICE SAFE CL
Safet
y
controller
APPLICATIONS
for safety light barriers and safety light curtain
APPROVALS
CE, TÜV, UL, C-UL
CONTACTS
4 safety semiconductor outputs (OSSD)
LED indicators for status and supply diagnostic
SPECIAL CHARACTERISTICS
Wearless semiconductor outputs, "AND" function
between several SAFE C possible, automatic start possible
LED
Power, channel 1, channel 2
24 V DC ( + 25 - 20 % )
OPERATING VOLTAGE
Overvoltage protection
POWER CONSUMPTION
ca. 3 W
START UP DELAY / FALLBACK TIME
<70 ms / <30 ms
CONTACT CAPACITY max.
total current bis 1,8 A
CONTACT CAPACITY min. at 24 V DC (*)
infinite
SIMULTANEITY
S12 before S22 <0,5 s / S22 before S12 infinite
ENVIRONMENTAL TEMPERATURE
-25°C to +55°C
SWITCHING CAPACITY
to 43 W
CONTACT SECURITY
short circuit proof
OPERATING MODE
(*) We offer all devices who have a CONTACT CAPACITY of
min. 100 mA at 24 V DC with hard gold-plated contacts.
In this way the CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
Even ESPE type 4 with OSSDs and relay contacts as well as ESPE type 2 with
one OSSD and test input are supported. Monitoring of movement direction is
available by different simultaneousnesses.
BWS - Empfänger
ESPE - receiver
24VAC/DC
S21
S34
A1 A2
S22
S12
44 34 24 14
Start
GND
PNP
PNP
S32
S11 S33
S35
S36 S37
FUNCTION CIRCUIT DIAGRAM
A1 A2
Power
Input circuits
S12 S22 S34 S35 S36
Output
circuits
Combination
circuit
S11 S21 S33
MCU1
<Controller 1>
MCU2
<Controller 2>
Safety output circuits
14
24
34
44
S32S37
Certifications according to
Safety relevant substance data
Depending on wiring (only max. achievable values are given)
EN ISO 13849-1/ EN 61508: PLe, Cat. 4 / SIL3
MTTFd: 163 years / high, DC: high, CCF: achieved,
PFH: 2,87*10
-9
1
/
h
, PFD: 2,01*10
-6
1
/
h,
SFF: 0,9573