Datasheet

Emergency stop and safety gate monitoring relays
Printing 11.03.2016
DEVICE
SAFE 4.2 eco
Emer
g
enc
y
sto
p
APPLICATIONS
and safety gate monitoring relay
APPROVALS
CE, TÜV, UL, C-UL
CONTACTS
3 normally open safety, 1 normally auxiliary closed
LED indicators for status and supply diagnostic
SPECIAL CHARACTERISTICS
Opposite polarity between channels
With and without start control (selectable)
LED
Power, channel 1 and channel 2
24 V AC / DC (electronic fuse)
OPERATING VOLTAGE
115, 230 V AC (with galvanic disconnection / transformer)
POWER CONSUMPTION
24 V DC: 1,5 W / AC: 3,6 VA
START UP DELAY / FALLBACK TIME
200 ms / <10 ms ready after time delay <0,5 s
CONTACT CAPACITY max.
5 A, 240 V AC, 24 V AC / DC
CONTACT CAPACITY min. at 24 V DC (*)
10 mA
SIMULTANEITY
ENVIRONMENTAL TEMPERATURE
-25°C to + 55°C
SWITCHING CAPACITY
1200 VA (resistive load)
CONTACT SECURITY
6,3 A quick acting or 4 A time lag
OPERATING MODE
(*) We offer all devices who have a CONTACT CAPACITY of
min. 100 mA at 24 V DC with hard gold-plated contacts.
In this way the CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
A supply voltage must be applied at terminals A1 and A2. The power
LED lights. Terminals S11, S12, S21 and S22 have to be wired up as
shown in the application examples. To start the unit, follow the
examples described in the start applications section. In series to the
start-button an external contactor can be controlled (see application
example). After activation the contacts 13-14, 23-24 and 33-34 are
closed, contact 41-42 is opened. The LEDs channel 1 and channel 2 are
lit.
For version with detachable clamps (screw - or cage clamps) ...
please ask our sales team!
Start
S21 S22
S11 S12
S34
U
B
A1
A2
Dual channel e-stop monitoring with cross circuit monitoring and
monitored start button
.
FUNCTION CIRCUIT DIAGRAM
S12
monitoring logic
~ ~
~
~
+
=
K1
electr. fuse
transformer
A1
(+)
A2
(-)
S34
S33 S11
K2
K2
13
K1
S22S21
3323 41
Certifications according to
Safety relevant substance data
Depending on wiring (only max. achievable values are given)
EN ISO 13849-1 / DIN EN 61508 / DIN EN 62061: PLe, Cat. 4 / SIL3
MTTFd: 910 years / high, DC: 99% / high, CCF: achieved,
PFH: 2,32*10
-9
1
/
h
, SFF: > 99%, HFT: 1

Summary of content (1 pages)