Operator`s manual
CS6 – English – 13
Operating Instructions
WARNING
Wear appropriate protective equipment such as latex
or rubber gloves, goggles, face shields, and respira-
tors when inspecting drains that might contain haz-
ardous chemicals or bacteria. Always wear eye pro-
tection against dirt and other foreign objects.
Do not operate the CS6 if you or the equipment are
standing in water. Operating the equipment while
in water increases the risk of electrical shock. Rub-
ber-soled, non-slip shoes can help prevent slipping
and electrical shock on wet surfaces.
Placement
When arranging your equipment at a work site, position
the CS6 so the keypad is easy to reach and the display
faces away from direct sunlight. Place the SeeSnake
camera reel near the pipe entrance to make it easier
to manipulate the push cable while viewing the display.
Make sure the CS6 and SeeSnake camera reel are sta-
ble.
NOTICE
When used outdoors or in wet locations,
use battery power only. Protect the bat-
tery from precipitation.
Connecting to a Camera Reel
The CS6 can connect to any SeeSnake camera reel with
the SeeSnake system cable.
1. Unwrap the system cable from the cable wraps.
2. Pull back the outer locking sleeve on the system
cable connector.
3. Align the connector ridge and plastic guide pin with
the socket and push the connector straight in.
4. Tighten the outer locking sleeve.
NOTICE
Only twist the outer locking sleeve. To
prevent damage to the pins, never bend
or twist the connector.
Guide Pin
Connector Ridge
Socket
Outer Locking Sleeve
5. Power on the system:
• Press the Power key to power on the system.
• Press the Autolog key to quick-start an inspec-
tion. Do two things with one key press: power on
the system and start recording Autolog video.
Note: A USB drive must be inserted to capture
media.