Operator`s manual

18 - English
TM
Table 8
Troubleshooting
Problem Probable Fault Solution
Camera video image not
seen
No power to SeeSnake
Check power is correctly plugged in� Check switch on
CS10�
Connections faulty
Check alignment and pins of connection from CS10 to
the SeeSnake Reel�
CS10 batteries low Recharge CS10 batteries� Switch to AC power
Flashing battery warning
appears
18 V Li-Ion batteries low Recharge batteries� Switch to AC power
Count accuracy
unreliable (CountPlus)
CountPlus settings
incorrect for Reel or cable
being used
Verify the settings are correct for the SeeSnake cable
length, cable diameter, and SeeSnake Reel being
used�
Counting from the wrong
zero-point
Confirm measurement from the intended zero-point�
Reset zero-point using the Zero Key (See page10).
Low battery warning
appears on screen
(CountPlus)
CountPlus battery dead or
near-dead
Replace 3V battery in the CountPlus (CR2450)
Low battery buzzer
sounds or both battery
LEDs turn red
CS10 batteries low Recharge CS10 batteries� Switch to AC Power
The “+” symbol appears
after the on-screen
distance measurement
(CountPlus)
Physical cable
measurement has
exceeded the cable
parameter in settings�
Verify the actual length of installed cable and reset the
SeeSnake Reel and cable settings in accordance with
the CountPlus Operator’s Manual�
SOS blinking on Power
Key LED
No video signal Reseat SeeSnake system cable connection�