Technical data
Preparation for commissioning
1.5 Rules for wiring with DRIVE-CLiQ
Commissioning Manual
38 Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
1.5.8 Sample wiring for servo drives
The following diagram shows the maximum number of controllable servo drives and extra
components. The sampling times of individual system components are:
● Active Line Module: p0115[0] = 250 µs
● Motor Modules: p0115[0] = 125 µs
● Terminal Module/Terminal Board p4099 = 1 ms
;
;
;
;
&RQWURO
8QLW
;
;
;
600
;
;
;
600
;
;
;
'00
;
;
;
;
600
;
;
;
600
;
60\
;
60[
;
60[
;
60[
;
60[
;
60[
;
60[
;
60\
;
60\
;
;
;
$/0
;
70[
;
Figure 1-11 Sample servo topology
Legend for topology example:
ALM = Active Line Module
SMM = Single Motor Module
DMM = Double Motor Module
SMx = Motor encoder
SMy = Direct measuring system
TMx = TM31, TM15DI/DO, TB30