Technical data

Diagnostics
3.3 Diagnostic buffer
Commissioning Manual
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
219
Booting procedures and booting status changes
In principle, only start and completion are recorded for booting procedures. Booting status
(see r3988) are only recorded when an end status arises that can only be exited by user
action (r3988 = 1, 10, 200, 250, 325, 370, 800). Booting statuses and booting status
changes are:
POWER ON
Error in booting (r3988 = 1)
Fatal error in booting (r3988 = 10)
Waiting for first commissioning (r3988 = 200)
Topology error in booting (r3988 = 250)
Waiting for entry of drive type (r3988 = 325)
Waiting until p0009 = 0 is set (r3988 = 370)
Boot status r3988 = <state at which 670 or 680> reached
Booting finished, cyclic operation
Reason for new boot < 0 = Internal reason; 1 = Warm start; 2 = Booting from saved data;
3 = Booting after download>
Drive reset via p0972 = <Mode>
Partial booting DO started <DO number>
Partial booting DO <DO number> finished
Commissioning procedures
Device commissioning: New status p0009 = <new value p0009>
Commissioning DO <DO number>: New status p0010 = <new value p0010>
Ram2Rom DO <0 for all DOs> started
Ram2Rom DO <0 for all DOs> completed
Project download started
DO <DO_Number> deactivated
DO <DO_Number> reactivated
Component <Component number> deactivated
Component <Component number> reactivated
Power Off/ Power On required after firmware update (DO <DO number>
Component < Component number >)
DO <DO-No> deactivated and not available
Component <component number> deactivated and not available