Technical data

Diagnostics
3.2 Diagnostics via STARTER
Commissioning Manual
206 Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
Parameterizing and operating the ramp-function generator
The function generator is parameterized and operated via the STARTER commissioning
tool.
Figure 3-1 "Ramp-function generator" initial screen
Note
Please refer to the online help for more information about parameterizing and operation.
Properties
Concurrent injection to several drives possible.
The following parameterizable signal shapes can be set:
Square-wave
Staircase
Triangular
Sinusoidal
PRBS (pseudo random binary signal, white noise)
An offset is possible for each signal. The ramp-up to the offset is parameterizable. Signal
generation begins after the ramp-up to the offset.
Restriction of the output signal to the minimum and maximum value settable.