Technical data

Diagnostics
3.1 Diagnostics via LEDs
Commissioning Manual
180 Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
3.1.2.10 Control Interface Board in the Active Line Module chassis format
Note
The description applies to Active Line Modules with order number 6SL3330–7Txxx–xAA0.
Table 3- 25 Meaning of the LEDs on the Control Interface Board in the Active Line Module
LED, state
Ready DC link
Description
Off Off The electronic power supply is missing or out of tolerance.
Off The component is ready for operation and cyclic DRIVE-CLiQ communication is taking
place.
Orange The component is ready for operation and cyclic DRIVE-CLiQ communication is taking
place.
The DC link voltage is present.
Green
Red The component is ready for operation and cyclic DRIVE-CLiQ communication is taking
place.
The DC link voltage is too high.
Orange Orange DRIVE-CLiQ communication is being established.
Red --- This component has at least one fault.
Note:
The LED is activated regardless of whether the corresponding messages have been
reconfigured.
Green / red
flashing light
0.5 Hz
--- Firmware is being downloaded.
Green / red
flashing light
2 Hz:
--- Firmware download is complete. Wait for POWER ON.
Green /
orange
or
red / orange
flashing light
2 Hz
--- Component detection using LED is activated (p0124)
Note:
Both options depend on the LED state when activated via p0124 = 1.
WARNING
Hazardous DC link voltages may be present at any time regardless of the state of the "DC
link" LED.
The warning information on the component must be carefully observed!