Technical data

Diagnostics
3.1 Diagnostics via LEDs
Commissioning Manual
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
175
3.1.2.5 Single Motor Module / Double Motor Module / Power Module
Table 3- 19 Meaning of the LEDs on the Motor Module
State Description, cause Remedy
Ready DC link
Off Off Electronic power supply is missing or outside
permissible tolerance range.
Off The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
Orange The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is present.
Green
Red The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
The DC link voltage is too high.
Check the line voltage
Orange Orange DRIVE-CLiQ communication is being established.
Red This component has at least one fault.
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
Remedy and acknowledge
fault
Green / red
flashing light
0.5 Hz
Firmware is being downloaded.
Green / red
flashing light
2 Hz
Firmware download is complete. Wait for POWER ON. Carry out a POWER ON
Green /
orange
or
Red / orange
Component detection via LED is activated (p0124).
Note:
Both options depend on the LED state when activated
via p0124 = 1.
DANGER
Hazardous DC link voltages may be present at any time regardless of the state of the "DC
link" LED.
The warning information on the component must be carefully observed!