3
This chapter describes the following diagnostic features of the SINAMICS S drive system:
Diagnostics via LEDs
Diagnostics via STARTER
Diagnostic buffer
Fault and alarm messages
3.1 Diagnostics via LEDs
3.1.1 Control Units
3.1.1.1 Description of the LED states of a CU 320-2
The various states of the Control Units CU320-2DP and CU320-3PN during power-up and
during operation are displayed using LEDs on the Control Unit. The duration of the individual
statuses varies.
Table 3- 1 LEDs
LED Function
RDY Ready
DP / PN PROFIdrive cyclic operation via PROFIBUS (DP) or PROFINET (PN)
OPT OPTION
If an error occurs, the booting procedure is terminated and the cause is indicated
accordingly via the LEDs.
Once the unit has successfully booted up, all the LEDs are switched off briefly.
Once the unit has booted up, the LEDs are controlled via the loaded software.