Technical data

Commissioning
2.13 Commissioning linear motors (servo)
Commissioning Manual
Commissioning Manual, (IH1), 01/2011, 6SL3097-4AF00-0BP1
131
2. Mechanical system
Is the axis easy to move over the complete traversing range?
Does the air gap between the primary and secondary section and the mounting
dimensions correspond to the motor manufacturer's data?
Hanging (suspended) axis:
If weight equalizing is used for the axis is this functioning?
Brake:
If a brake is being used, is it correctly controlled (see the SINAMICS S120 Function
Manual)?
Traversing range limiting:
Are the mechanical end stops available and tightly bolted to both ends of the
traversing path?
Are the moving feeder cables correctly routed in a cable drag assembly?
3. Measuring system
Which measuring system is being used?
_ _ _ _ _ _ _ _ _ _ _ _
Absolute or incremental? abs incr
Grid spacing _ _ _ _ _ _ _ _ _ _ µm
Zero marks (number and position)_ _ _ _ _ _ _ _ _ _ _ _
Where is the positive drive direction?
Where is the positive counting direction of the measuring system?
Invert (p0410)? yes / no