Specifications

14
Maintenance
WARNING: For your own safety, turn switch “OFF”
and remove plug from power source outlet before
maintaining or lubricating your sawdust collection
system.
WARNING: To reduce the risk of injury from electric
shock or suddenly starting unit, always remove
switch key and keep unplugged while unit is disas-
sembled in any way. Always reassemble with rec-
ommended parts before plugging unit in.
Chip Collecting Bag Removal
1. Push band up and slide opposite edge to the middle
opening.
2. Lower band carefully through opening as shown.
Deposit chips in appropriate container.
CAUTION: Wear safety goggles ANSI Z87.1 (or in
Canada CSA Z94-3-M88) to protect your eyes prior
to commencing operation.
3. Reconnect the chip collecting bag by sliding the band
through the hole and slide the opposite side under dust
chute extension. Seat as shown.
Filter/Dust Bag Removal
CAUTION: If using this dust collection system to
help keep airborne wood dust in heavy usage
within acceptable limits, you must regularly moni-
tor airborne dust and maintain dust collection sys-
tem to avoid exceeding dust limits. Each
application is unique. Your maintenance schedule
must, therefore, be tailored to your specific use of
this dust collection system.
1. Shake the filter/dust bag so the fine dust falls into lower
chip collecting bag.
2. Disconnect the adjustable band clamp by releasing the
spring lever clamp.
3. Remove the filter/dust bag and deposit all fine dust in
an appropriate container.
4. Reconnect the bag carefully so the clamp wraps
around the bag on all sides. Adjust the lever to the
fourth hook and fasten securely.
Chip Bag
Adjustable
Band Clamp
Dust Bag
Dust Bag
Holder