Brochure

800.769.7743 l RIDGID.com
See complete catalog or visit RIDGID.com for full RIDGID product line.
Standard Equipment
FR-30 A-Frame Receiver
FT-103 Transmitter
Ground Stake
Red and Black Test Leads
Carry Cases
Batteries
Operator’s Manual Pack
FT-103 Transmitter Specifications
Operating Frequencies
............. Direct Fault Finding: 797 Hz - “dFF” displayed
Path locating: 128 Hz, 1 kHz, 8 kHz, 33 kHz, 93 kHz
Direct Connect: 128 Hz, 1 kHz, 8 kHz, 33 kHz, 93 kHz
Inductive Clamp: 8 kHz, 33 kHz, 93 kHz
Broadcast Inductive: 33 kHz, 93 kHz
Load Range ............................... 5 Ω to 2M Ω
Output Power........................... Up to 3 Watts (low, medium and high settings)
Output Voltage
........................ 5 Volts - 600 Volts
Power Supply ........................... 8 × C-Cell Batteries (included)
Dimensions (LxWxH) ................ 8.5" x 5.8" x 2.5"
FR-30 A-Frame Receiver Specifications
Fault Finding Depth
................ Up to 20' (depending on conditions)
Fault Finding Length ................. Up to 3 miles (depending on conditions)
Display .................................... Black and White LCD
Power Supply
........................... 6 × AA Batteries
Dimensions (LxWxH)
................ 30.3" x 30.4" x 1.5"
27