User manual
S9922 3G/4G Router User Manual
RICON: Mobile Connect Tecnology
Parameter
Details
Operation
Server: 3G router act as
TCP/UDP server
Client: 3G router act as
TCP/UDP client
DDPClient: 3G router act as
UDP client with RICON protocol.
Local Port
Local port of TCP/IP
connection
Specify the port number
Protocol
Protocol of TCP/IP connection
Select protocol
Received
Timeout
Receive data coming from 3G
network timeout, then pack
received data
Specify time to pack data
RS232 Data
Timeout
Receive data coming from
RS232 interface timeout, then
pack received data
Specify time to pack data
Server IP or
Domain
Server IP or Domain of TCP/IP
connection
Input IP or domain
Server Port
The center side TCP/IP
connection server port
Input port number
Connect Interval
The interval DTU retry to
connect to TCP/IP connection
server
Input interval time
Retry Times
DTU retry connection after
failed connect to server
Input the number of times
Heartbeat Data
Data to maintain connection
Input any characters except “!”
Rate
Serial port setting
Acording to connected device
Parity
Serial port setting
Acording to connected device
Databit
Serial port setting
Acording to connected device
Stopbit
Serial port setting
Acording to connected device
Step 4 Single click “save” icon to finish “DTU” configuration
DTU will start to work when modem is online if it is enabled.
---END