Operating instructions

32DDO05.A
3 -
1
III. MAINTENANCE
egular maintenance of the RICON RDO2900 Series Internal Power Swing Door Operators will
provide optimum performance. During the Ricon warranty period, maintenance inspections
must be performed by an authorized Ricon service technician at least once every six months, or
sooner depending on usage. After the warranty period, maintenance inspections are recom-
mended at the same time intervals.
WARNING!
THIS RICON PRODUCT IS HIGHLY SPECIALIZED. MAINTENANCE AND REPAIRS MUST
BE PERFORMED BY AN AUTHORIZED RICON SERVICE TECHNICIAN USING RICON RE-
PLACEMENT PARTS. MODIFYING OR FAILING TO PROPERLY MAINTAIN THIS PRODUCT
WILL VOID THE WARRANTY, AND MAY RESULT IN UNSAFE OPERATING CONDITIONS.
TO MAINTAIN THE WARRANTY, THIS PRODUCT MUST BE INSPECTED AT LEAST EVERY
SIX MONTHS, OR SOONER DEPENDING ON USAGE.
A. MAINTENANCE INFORMATION
Additional maintenance information is available in the RDO2900 Series Internal Power
Swing Door Service manual, part number 32DDO06. This manual is available from Ricon in
printed hard copy, or at the Ricon website in PDF format. The website is located at
www.riconcorp.com.
A. MAINTENANCE SCHEDULE
TABLE 3-1: SIX-MONTH MAINTENANCE CHECK
INSPECTION AREA ACTION
Rod ends and hex rod.
Clean, tighten, and lubricate with light oil as
needed.
Check door motion for complete travel. Adjust as needed.
Check all fasteners for tightness. Tighten as needed.
Check electrical crossover cable for inter-
ference with moving members.
Adjust and secure as needed.
Check manual operation of power door
operators.
Verify proper operation.
THE FOLLOWING STEPS REQUIRE REMOVAL OF THE DOOR PANELS
Check spur gear and bushings for signs
of wear.
Replace if needed.
Check wiring and limit switches for proper
connection and/or interface points.
Adjust as required.
END OF TABLE
R