Service manual
Bit Switches
SM 93 M381
Fax Option
Type SP5200
(M381)
G3 Switch 0B - Not used (do not change the settings).
G3 Switch 0C - Not used (do not change the settings)
G3 Switch 0D - Not used (do not change the settings).
G3 Switch 0E [SP No 1-105-015]
0-7
Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the
3-second CNG interval.
High order bit
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) < N < FF (2250
ms)
Low order bit
3000-3700ms: 3000+50xNms
3000 + 50 x Nms 00 (3000 ms) < N < 0E (3700 ms)
G3 Switch 0F [SP No. 1-105-016]
No FUNCTION COMMENTS
0
Alarm when an error occurred
in Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each
error communication, change this bit to "1".
1
Alarm when the handset is
off-hook at the end of
communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to "1".
2
Not used
Do not change the settings.
4
Sidaa manual calibration
setting
0: Off
1: On
1: manually calibrates for communication with a
line, whose current change occurs such as an
optical fiber line.
5-7
Not used
Do not change the settings.