Service manual

Bit Switches
M381 56 SM
System Switch 1E [SP No. 1-101-031]
No FUNCTION COMMENTS
0
Communication after the
Journal data storage area has
become full
0: Impossible
1: Possible
0: When this switch is on and the journal history
becomes full, the next report prints. If the journal
history is not deleted, the next transmission cannot
be received. This prevents overwriting
communication records before the machine can
print them.
1: If the buffer memory of the communication
records for the Journal is full, fax communications
are still possible. But the machine will overwrite
the oldest communication records.
Note: This setting is effective only when Automatic
Journal printout is enabled but the machine cannot
print the report (e.g., no paper).
1
Action when the SAF memory
has become full during
scanning
0: The current page is erased.
1: The entire file is erased.
0: If the SAF memory becomes full during
scanning at the memory transmission, the
successfully scanned pages are transmitted.
1: If the SAF memory becomes full during
scanning at the memory transmission, the file is
erased and no pages are transmitted.
This bit switch is ignored for parallel memory
transmission.
2
RTI/CSI display priority
0: RTI 1: CSI
This bit determines which identifier, RTI or CSI, is
displayed on the LCD while the machine is
communicating in G3 non-standard mode.
3
File No. printing
0: Enabled
1: Disabled
1: File numbers are not printed on any reports.
NOTE: The file numbers may not be printed in the
sequential order. If a customer does not like this
numbering, select "0".