Service manual
Service Call Conditions
M052/M053/M054 6-30 SM
995 D CPM setting error
-001
Defective BICU
Input the serial number with SP5811-004, and turn the main power switch
off/on.
-002
Defective NVRAM on the controller
Defective controller
1. Install a new NVRAM, and turn off and on the main power switch
after SC995-002 has occurred.
2. Reinstall the previous NVRAM or download the information with
SP5825-001, after that turn the main power off and on.
-003
Incorrect type controller installed
Defective controller
Replace the controller board with the correct type.
-004
Incorrect model controller installed.
Replace the controller with the correct model.
997 B Application function selection error
Application selected by the operator did not start or end normally due to a
software problem. An option required by the application may not be
installed.
Confirm which devices are required for the application.
Make sure all devices are configured correctly.
If the problem is with the fax unit, the nesting of the fax group may be
too complicated