Service manual
Service Call Conditions
SM 6-13 M052/M053/M054
Trouble-
shooting
622 D Paper tray unit communication error
623 D 2nd Paper tray unit communication error
624 D 3rd Paper tray unit communication error
- -
While the BICU communicates with an optional unit, an SC code is
displayed if one of following conditions occurs.
The BICU receives the break signal which is generated by the
peripherals only just after the main switch is turned on.
When the BICU does not receive an OK signal from a peripheral after
sending a command to it.
Harness disconnected or broken
BICU defective
External noise
Main board defective in the peripherals
641
CTL
D
BICU control data transfer abnormal
A sampling of the control data sent from the BCU reveals an
abnormality.
Controller board defective
External noise
BCU board defective
Check the connection between the controller board and BICU.
Replace the controller board.
Replace the BICU.