Service manual

Copier
M052/M053/M054 2-12 SM
Meter Click
Charge: Life
Disp:AIO
SP5-930-003
Enables or disables the PM alert for
the AIO.
If this SP is enabled, an alert
message is displayed when the AIO
needs to be replaced.
"1": No alert
Counter method SP5-045-001
Specifies if the counting method
used in meter charge mode is
based on develaibopments or
prints.
“1”: Prints
Parts
Replacement
Operation Type
SP5-067-001
Selects the service maintenance or
user maintenance for the
maintenance kit.
"1: User "
Service Tel:
Telephone
/Facsimile
SP5-812-001
and -002
-001: shows or sets the telephone
number of the service
representative.
-002: shows or sets the fax number
of the service station. The number
is printed on the counter list when
the "Meter Click Charge" is
enabled. User can send a fax
message with the counter list.
-