Service manual

Service Call Conditions
SM 6-5 M052/M053/M054
Trouble-
shooting
144 D
SBU connection error
Connection to the SBU could not be confirmed, possibly due to a defect in
the BICU detection port.
Harness connection at BICU or SBU loose, broken, defective
BICU defective
SBU defective
161
-001
D
IPU Error 1
The self-diagnostic test detected an error at the BICU at power on, or after
the machine returned from energy save mode.
Harness between SBU and BICU loose or broken
BICU defective
SBU defective
161
-002
D
IPU Error 2
The machine does not detect RI answer from BICU.
Harness between SBU and BICU loose or broken
BICU defective
SBU defective
165 B
Copy Data Security Unit error
An error occurred when the machine attempted to recognize the Copy
Data Security Unit board.
Check installation of Copy Data Security (CDS) Unit
CDS unit not correct type for the machine
CDS unit defective