Service manual
Service Call Conditions
M052/M053/M054 6-4 SM
141 D
Black level correction error
Black level correction could not be set properly during automatic
adjustment.
Harnesses at the SBU or BICU loose, broken, defective.
SBU defective
142 D
White level correction error
White level correction could not be set properly during automatic
adjustment.
Harnesses at SBU or BICU loose, broken, defective
Anti-condensation heater (option) in scanner unit not operating
Exposure lamp harness, loose, broken, defective
Exposure lamp defective
Scanner drive error
SBU defective
143 C
SBU auto adjust error
The machine could not acquire the white or black peak level setting at
power on.
Harnesses at SBU or BICU loose, broken, defective
Anti-condensation heater (option) in scanner unit not operating
Exposure lamp harness, loose, broken, defective
Exposure lamp defective
Scanner drive error
SBU defective