Service manual

System SP5-xxx
SM 5-65 M052/M053/M054
System
Maintenance
Reference
157
Dial Up Password
Use this SP to set a password for access to remote dial up. Follow these rules
when setting a user name:
Name length: Up to 32 characters
Spaces and # allowed but the entire entry must be enclosed by double
quotation marks (").
161
Local Phone Number
Use this SP to set the telephone number of the line where embedded RCG-M
is connected. This number is transmitted to and used by the Call Center to
return calls.
Limit: 24 numbers (numbers only)
162
Connection Timing Adjustment: Incoming
When the Call Center calls out to an embedded RCG-M modem, it sends a
repeating ID tone (*#1#). This SP sets the time the line remains open to send
these ID tones after the number of the embedded RCG-M modem is dialed up
and connected.
[0 to 24 / 1 / 1 /step]
The actual amount of time is this setting x 2 sec. For example, if you set "2"
the line will remain open for 4 sec.
163
Access Point
This is the number of the dial-up access point for RCG-M. If no setting is done
for this SP code, then a preset value (determined by the country selected) is
used.
Default: 0
Allowed: Up to 16 alphanumeric characters