Service manual
System SP5-xxx
SM 5-59 M052/M053/M054
System
Maintenance
Reference
063
Proxy Host
This SP sets the address of the proxy server used for communication
between Embedded RC Gate-N and the gateway. Use this SP to set up or
display the customer proxy server address. The address is necessary to set
up Embedded RC Gate-N.
The address display is limited to 128 characters. Characters beyond
the 128 character are ignored.
This address is customer information and is not printed in the SMC
report.
064
Proxy Port Number
This SP sets the port number of the proxy server used for communication
between Embedded RC Gate-N and the gateway. This setting is necessary to
set up Embedded RC Gate-N.
This port number is customer information and is not printed in the
SMC report.
065
Proxy User Name
This SP sets the HTTP proxy certification user name.
The length of the name is limited to 31 characters. Any character
beyond the 31st character is ignored.
This name is customer information and is not printed in the SMC
report.
066
Proxy Password
This SP sets the HTTP proxy certification password.
The length of the password is limited to 31 characters. Any character
beyond the 31st character is ignored.
This name is customer information and is not printed in the SMC
report.