Service manual
System SP5-xxx
M052/M053/M054 5-52 SM
5515
[SC/Alarm Setting]
With @Remote in use, these SP codes can be set to issue an SC call when
an SC error occurs. If this SP is switched off, the SC call is not issued when
an SC error occurs.
001 SC Call
[0 or 1 / 1 / - ]
0: Off, 1: On
002 Service Parts Near End Call
[0 or 1 / 1 / - ]
0: Off, 1: On
003 Service Parts End Call
004 User Call
[0 or 1 / 1 / - ]
0: Off, 1: On
006 Communication Test Call
007 Machine Information Notice
008 Alarm Notice
[0 or 1 / 1 / - ]
0: Off, 1: On
009 Non Genuin Tonner Alarm
[0 or 1 / 1 / - ]
0: Off, 1: On
010 Supply Automatic Ordering Call
011 Supply Manegement Report Call
012 Jam/Door Open Call
Memory Clear (SP5-801)
The following tables list the items that are cleared. The serial number information,
meter charge setting and meter charge counters are not cleared.
5730 [Extended Function Setting]
010 Expiration Prior Alarm
[0 to 999 / 20 / 1 day/step]
Specifies the expiration alarm timing.