Service manual
System SP5-xxx
SM 5-51 M052/M053/M054
System
Maintenance
Reference
134 Interval :A5
142 Interval :B5
164 Interval :LG
166 Interval :LT
172 Interval :HLT
5508* [CC Call] *CTL -
001*
Jam Remains
0: Disable, 1: Enable
Enables/disables initiating a call for an unattended paper jam.
002*
Continuous Jams
0: Disable, 1: Enable
Enables/disables initiating a call for consecutive paper jams.
003*
Continuous Door Open
0: Disable, 1: Enable
Enables/disables initiating a call when the front door remains open.
011*
Jam Detection: Time Length
[3 to 30 / 10 / 1 minute /step]
Sets the time a jam must remain before it becomes an “unattended paper
jam”. This setting is enabled only when SP5508-004 is set to "1".
012*
Jam Detection: Continuous
Count
[2 to 10 / 5 / 1 /step]
Sets the number of consecutive paper jams required to initiate a call. This
setting is enabled only when SP5508-004 is set to "1".
013*
Door Open: Time Length
[3 to 30 / 10 / 1 /step]
Sets the length of time the door remains open before the machine initiates a
call.
This setting is enabled only when SP5-508-004 is set to "1".