Service manual

System SP5-xxx
M052/M053/M054 5-50 SM
5504 [Jam Alarm] *CTL -
001
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a set
number of copied sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 - *CTL
[0 to 255 / 27 / 100 copies /step]
5507
[Supply Alarm] *CTL -
Enables or disables the notifying a supply call via the @Remote.
001 Paper Supply Alarm
0: Off, 1: On
002 Staple Supply Alarm
0: Off, 1: On
004 Maintenance Kit Alarm
0: Off, 1: On
009 Cartridge Supply Alarm
0: Off, 1: On
080 Toner Call Timing
Changes the timing of the "Toner Supply Call" via
the @Remote, when the following conditions
occur.
0: At replacement
1: At near end
128 Interval :Others
[250 to 10000 / 1000 / 1 /step]
133 Interval :A4