Specifications

6.4 PRESSURE ROLLER/CLEANING ROLLER
1. Remove the hot roller. (See Hot Roller/Fusing Lamp.)
2. Remove the exit guide plate [A] (1 screw).
3. Check the height position of the entrance guide plate [B] (the upper
position is standard) and remove it (1 screw).
4. Remove the pressure roller [C].
5. Remove the cleaning roller [D].
[B]
[D]
[C]
[A]
A193R026.wmf
1 August 1996 FUSING/EXIT
6-25