Service manual

PRINTER CONTROLLER
SM 3-5 B358
Installation
20. Install the paper height sensor actuator [A] on the bottom plate shaft [B] of each
paper tray.
21. Reassemble the machine.
Paper Limit Sensor and Paper Sensor Installation
If the optional bridge unit has been installed, skip steps 22 and 23.
22. Peel off the black tape [C] from the anti-static brush [D], then pull out the cable
[E].
23. Connect the cable to the sensor [F], then install the paper limit sensor unit [G]
(2 screws).
B358I514.WMF
B358I516.WMF
B358I515.WMF
[A]
[B]
[F]
[G]
[C]
[E]
[D]