Specifications
Product Support Guide
D146 / D147 / D148 / D149 / D150/ D176 / D177
Ver.2.1.1 Page 26 of 51 3/5/2014
Subject to change without notice
Storage/Transportation
Storage Condition
Temperature
-30 to 45 / 86 to 113
C/F
Humidity
Less Than 85% RH
% RH
Storage Period
Max 12 Months
Max Stack
4 Cartons
Transportation Condition
Temperature
-30 to 45 / 86 to 113
C/F
Humidity
15% to 95% RH
% RH
Max Stack
2 Cartons
Installation Environment
Temperature
10 to 32 / 50 to 89.6
C/F
Humidity
15% to 80% RH
%RH
Luminance
Less than 1500
Lux
Ventilation
More than 3 times/hr/people
Times/hr/
people
Remarks
* Store in a dry, dark place where temperature does not exceed 45C / 113 F on continuance storage/transportation conditions
* Do not store more than 12 hours under the temperature between 40 to 45C / 105 to113 F. (for Developer Y/M/C, between 41 to 50C /
105.8 to 122 F)
* Do not store more than a month under the temperature between 35 to 40C / 96.8 to 104 F.
* Do not store more than 14 days under the temperature 40C / 104 F and the humidity 70%. (except Developer Y/M/C)
* Ideal temperature of toner use is between 10C / 50 F to 32C / 89.6
Parts / Special Tools / Maintenance
PM Parts / Yields
Mainframe
Unique/Common
U: Unique for this model
C: Common with listed model
Part Number
Description
Q’ty/
Unit
PM Interval
Unique or
Common
PCDU
D1862208
Photo Conductor Unit - K
1
400k
U
D1862209
Photo Conductor Unit - CMY
1
270K
D1863050
Development Unit - K
1
600K
D1863070
Development Unit - M
1
270K
D1863060
Development Unit – C
1
270K
D1863080
Development Unit - Y
1
270K
Transfer
D1496001
ITB Unit
1
600K
U
D1496140
ITB Cleaning Unit
1
300K